2011 Fairchild Semiconductor Corporation
www.fairchildsemi.com
FT3001 Rev. 1.0.4
4
FT3001
—
Reset
Timer
with
Configurable
Delay
Recommended Operating Conditions
The Recommended Operating Conditions table defines the conditions for actual device operation. Recommended
operating conditions are specified to ensure optimal performance to the datasheet specifications. Fairchild does not
recommend exceeding them or designing to Absolute Maximum Ratings.
Symbol
Parameter
Conditions
Min.
Max.
Unit
VCC
Supply Voltage
TA = 0C to +85C
1.65
5.00
V
TA = -25C to +85C
1.7
5.0
TA = -40C to +85C
1.8
5.0
tVCC_REC
Vcc Recovery Time After Power
Down
Vcc = 0 V after power down, then rising to
0.5 V
5
ms
VIN
Input Voltage
(2)
/SR0, /SR1
0
5.0
V
VOUT
Output Voltage
/RST1, RST2 High or Low
0
VCC
V
/RST1, RST2, VCC = 0 V
0
5.0
IOH
DC Output Source Current
RST2, 1.8 V ≤ VCC ≤ 3.0 V
-100
A
RST2, 3.0 V ≤ VCC ≤ 5.0 V
-500
IOL
DC Output Sink Current
/RST1, RST2, VCC = 1.8V to 5.0 V
+500
TA
Free Air Operating Temperature
-40
+85
C
JA
Thermal Resistance
MLP-8
245
°C/W
UMLP-10
200
Notes:
2.
All unused inputs must be held at VCC or GND.
DC Electrical Characteristics
Unless otherwise specified, conditions of TA=-40 to 80C with VCC=1.8 - 5.0V OR TA=-25 to 85C with VCC=1.7 – 5V OR
TA=0 to 85C with VCC=1.65 – 5V produce the performance characteristics below.
Symbol
Parameter
Condition
Min.
Max.
Unit
V
IH
Input High Voltage
(3)
/SR0, /SR1
0.8 x VCC
V
IL
Input Low Voltage
/SR0, /SR1
0.2 x VCC
V
IH
Input High Voltage
DSR0, DSR1
0.8 x VCC
V
IL
Input Low Voltage
DSR0, DSR1
0.2 x VCC
V
OH
High Level Output Voltage
RST2, IOH=-100 A
0.8 x VCC
V
RST2, IOH=-500 A, VCC=3.0
to 5.0V
0.8 x VCC
V
OL
Low Level Output Voltage
RST2, IOL=500 A
0.3
V
/RST1, IOL=500 A
0.3
I
IN
Input Leakage Current
VIN =0.0 V or 5.0 V
1
A
ICC
Quiescent Supply Current (Timer
Inactive)
/SR0 or /SR1=VCC
1
A
ICC
Dynamic Supply Current (Timer Active)
/SR0 and /SR1=0 V
100
A
Note:
3.
/SR0 and /SR1 HIGH levels should be referenced to the same VCC rail supplying the FT3001.